Safety Information
SECTION 1: PRODUCT IDENTIFICATION: OZONE
| Parameters | Information |
|---|---|
| Product | Ozone |
| Chemical formula | O₃ |
| Synonyms | Triatomic oxygen |
| Chemical family | Gaseous oxidizer |
| N° CAS | 10028-15-6 |
| NIOSH | RTECS RS8225000 |
| Manufacturer | Glacier Ozone |
SECTION 2: COMPOSITION AND PHYSICAL DATA
| Molecular properties | Value | Unit |
|---|---|---|
| Molecular weight | 48,0 | g/mole |
| Specific gravity | 2,144 | g/L |
| Relative gas density | 1,66 | - |
| Ionization potential | 12,52 | eV |
| Thermal properties | Value | Unit |
|---|---|---|
| Melting point | -192,5 | °C |
| Boiling point | -111,9 | °C |
| Vapour pressure | >1 | atm |
| Physical properties | Description |
|---|---|
| Water solubility | 0,001% (0°C) |
| Appearance and odour | Colourless to bluish gas with a strong, pungent odour. Ozone is heavier than air. |
SECTION 3: HEALTH HAZARD INFORMATION
DANGER
Gaseous oxidizer – Health hazard by inhalation
| Exposure limit values | Organization | Value | Duration |
|---|---|---|---|
| VLE/MPT | OSHA/REL NIOSH | 0,1 ppm (0,2 mg/m³) | 8 h/day, 40 h/week |
| CNESST | (QUEBEC/CANADA) | maximum value 0.1 ppm (0.2 mg/m³) | |
| VECD | OSHA/NIOSH | 0,3 ppm (0,6 mg/m³) | 15 min |
| DIVS | OSHA/NIOSH | 5 ppm (10 mg/m³) | - |
| Characteristic | Information |
|---|---|
| Olfactory threshold | 0,01 to 0,04 ppm |
| Warning properties | Adequate |
WARNING PROPERTIES:
The odour threshold is detectable between 0.01 and 0.04 ppm, which indicates it has adequate warning properties. Health Canada advises avoiding prolonged exposure above this threshold.
EFFECTS OF OVEREXPOSURE
Symptoms: Irritation of the nose and throat, and may cause shortness of breath and/or coughing, headaches, fatigue, drowsiness, and inflammation of the upper respiratory tract.
SECTION 4: FIRST AID MEASURES
| Inhalation | Description |
|---|---|
| Emergency procedure | Move the person to a well-ventilated area with fresh air. If breathing is difficult, a qualified person should administer oxygen. If symptoms persist, seek medical attention immediately. |
SECTION 5: FIRE AND EXPLOSION HAZARD DATA
| Combustibility properties | Valeur |
|---|---|
| Explosiveness | Ozone is generated from air at concentrations of 1–2% by weight. At these concentrations, ozone is not explosive. |
| Flash point | N/D |
| Auto-ignition temperature | N/D |
| Flammability limits in air | N/D |
SECTION 6: ACCIDENTAL RELEASE MEASURES
| Emergency procedures | Description |
|---|---|
| Immediate measures | Please evacuate the area, and open doors and windows to let the room ventilate naturally. Ozone breaks down within a few minutes to a few hours, but the time varies based on its concentration and the ventilation conditions. To speed up the dissipation of ozone, mechanical ventilation is highly recommended. |
SECTION 7: REACTIVITY DATA
| Stability and reactivity | Information |
|---|---|
| Stability | Unstable. Slowly decomposes into oxygen from which it was formed. |
| Conditions to avoid | Avoid concentrating ozone to levels (>20%) where its reactivity and decomposition rate accelerate. |
| Incompatibility | Ozone is chemically reactive with all oxidizable materials, both organic and inorganic. In the presence of certain atmospheric pollutants (e.g., VOCs), ozone can generate secondary byproducts such as aldehydes or ketones. |
SECTION 8: PROTECTION AND PRECAUTIONS
| Required ventilation type | Recommandation |
|---|---|
| General ventilation | General ventilation is strongly recommended. Ensure an adequate supply of fresh air and avoid working in areas where ozone is produced, unless the ozone concentration is below the occupational exposure limit (OEL) or time-weighted average (TWA). Mechanical ventilation is necessary for enclosed spaces. |
| Respiratory protection | Specification |
|---|---|
| Respirator | Wearing a respirator may be required when source control measures are not technically feasible. The use of a respirator that complies with NIOSH or CSA standards may be necessary when concentrations exceed the ceiling value set by the CNESST (0.1 ppm). Use an approved respirator that complies with current safety standards (e.g., NIOSH, CNESST, or CSA) and is appropriate for the type and level of exposure. Standard filtering masks (e.g., N95) do not protect against ozone. Only an approved respirator (CSA/NIOSH) is effective. |
DISCLAIMER
For industrial and commercial use only.
Not intended for residential or medical use.
Exposure to ozone must be limited and comply with Health Canada and CNESST recommendations (maximum value: 0.1 ppm).
Adequate ventilation is required during use.
The information and recommendations contained in this safety data sheet are based on sources deemed reliable and accurate. However, Glacier Ozone makes no warranty, express or implied, as to the accuracy of the information or the results that may be obtained from its use. It is the user's responsibility to determine whether the product is suitable for the intended use and to comply with all applicable Canadian laws, regulations, and standards (CNESST, Health Canada, CSA).